XXV SEMINÁRIO NACIONAL DE
PRODUÇÃO E TRANSMISSÃO
DE ENERGIA ELÉTRICA


BELO HORIZONTE - MG

10 A 13

NOVEMBRO/2019
2019 - EXPOMINAS
Grupo: GGH
Tema: Aspectos de Manutenção e Gestão de Equipamentos e Estruturas Hidráulicas:
Título: Histórico de Falhas Estruturais e Soluções Desenvolvidas nas Grades da Tomada Dágua da Usina Hidrelétrica Gov. José Richa.
Autores: Diego Orlando de Bortoli(1); Rodrigo de Campos(1); Jose Boz Neto(1); Romildo Tristante(1); Leonardo Enta(1)
Instituições: COPEL GET(1)
Resumo: O projeto e a confecção dos painéis de grades da tomada d’água (TDA) da Usina Hidrelétrica Governador José Richa (UHE GJR) seguiram as normas técnicas vigentes e recursos tecnológicos da época da sua construção na década de 90. Mesmo assim, em seus 20 anos de operação, estes equipamentos tiveram ocorrências com trincas e quebras de segmentos metálicos em seus painéis. Neste período, a COPEL realizou diversos estudos e melhorias buscando soluções, a fim de eliminar o modo de falha, sendo que após um estudo bastante estruturado com coleta de dados e análises computacionais, alcançou-se ganhos significativos de confiabilidade nestes equipamentos.